By Hector M., Service expert Bensalem office
Job at a glance
- Location
- Bensalem, PA
- Service
- Panel Replacement
- When
- August 2026
- Service expert
- Hector M.
- Called about
- a circuit that had stopped working
- Service size
- 200 amp
- Panel brand
- Eaton
- Visits
- 1
- Options offered
- 2
- Inspection
- Passed
- Inspection passed
- No
What this type of job typically costs
$7,425 to $11,875
Panel replacement, everything on the job
From 856 jobs we completed in the last 18 months.
The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.
Range updated November 10, 2026.
About this service →A Bensalem client called after noticing their garage refrigerator had stopped working, shortly after power washers had been at the property earlier that day. They suspected a circuit issue and wanted to find out what was causing the loss of power.
The client's problem
The client had lost power to the garage refrigerator and outside lighting, and they were concerned the recent power washing work might have caused or exposed an electrical problem.
What our service expert found
When the service expert opened the electrical panel for inspection, they found rust and corrosion inside the equipment, breakers with two wires under one screw (known as double taps), and loose connections throughout. These conditions indicated the panel had deteriorated over time and was no longer providing safe, reliable power distribution. Double tapped breakers can cause overheating and intermittent power loss, while corrosion and loose connections increase the risk of arcing and further circuit failures.
Options we presented
The service expert presented two options to address the panel issues and restore reliable power to the home.
Install a new 200 amp panel with whole home surge protection included (the client chose this one)
Install a new 200 amp panel without surge protection
The solution
The client chose the panel replacement with surge protection. The team installed a new Eaton 200 amp, 30 space main breaker panel, which provided better circuit separation and allowed tandem breakers to be replaced with individual dedicated breakers. Kitchen circuits that had been sharing tandem breakers were converted to individual dedicated breakers for proper separation. An Eaton whole home surge protective device was installed at the service entrance to protect the home's electrical system and connected equipment. All circuits were properly terminated and labeled upon completion.
Work performed
Inspected existing panel and tested for proper voltages
Removed deteriorated panel with rust, corrosion, and double tapped breakers
Installed new Eaton 200 amp, 30 space main breaker panel
Replaced tandem breakers with individual dedicated breakers for kitchen circuits
Installed whole home surge protective device at service entrance
Properly terminated and labeled all circuits
What we installed
- Eaton BRP30B200 200 Amp Plug On Neutral 30 Space 60 Circuit Indoor Main Breaker Loadcenter with Cover
- Eaton CHSPT2ULTRA Type 1 Surge Protective Device
Why pricing varies
No two homes are wired the same. On this job, the price came down to:
- Service size and whether the main breaker rating changes
- Condition of the existing enclosure, bus bars and breakers
- Grounding and bonding that must be brought up to current code at the same time
- Service entrance conductors and the meter can, when they are part of the scope
- Utility coordination and permit requirements in the jurisdiction
- Surge, AFCI and GFCI protection added during the changeout
- Panel brand and breaker selection
- Accessibility of the panel location and any drywall or masonry work around it
- Code corrections found once the deadfront is off
A service expert prices your job after seeing it, and you approve the price before any work starts.
Why it matters in Bensalem
Older panels in Bucks County homes can develop corrosion and connection problems over time, especially when exposed to moisture or humidity from nearby garages or exterior walls. Double tapped breakers are a common issue in aging panels and can lead to overheating, tripped circuits, and potential fire hazards. Replacing a deteriorated panel with modern equipment and adding surge protection helps ensure the electrical system can safely handle the demands of today's appliances and electronics.
Common questions
What is a double tapped breaker and why is it a problem?
A double tapped breaker has two wires connected under a single screw terminal, which most breakers are not designed to handle. This can cause loose connections, overheating, and intermittent power loss. It is a common code violation found in older panels.
Can corrosion inside an electrical panel cause circuits to stop working?
Yes, rust and corrosion can interfere with electrical connections and cause breakers to malfunction or fail entirely. Corrosion also increases resistance, which can lead to overheating and potential fire hazards over time.
Why would I need to replace my panel instead of just fixing the bad breaker?
When a panel shows widespread issues like corrosion, loose connections, and improper wiring, replacing individual components may not address the underlying problems. A new panel provides a fresh start with proper circuit separation and modern safety features.
What does a whole home surge protector do?
A whole home surge protector installed at the service entrance helps shield your electrical system and connected devices from voltage spikes caused by lightning, utility switching, or other events. It provides a first line of defense for appliances, electronics, and other equipment throughout the home.
The service expert on this job
Hector M.
Service expert
Hector is a service expert with Thomas Edison Electric. He has completed more than 950 jobs for clients in Philadelphia, Bucks and Montgomery counties. His most common calls are lighting and ceiling fans, outlets and switches, troubleshooting and panel upgrades.
More about Hector →Reviewed by a licensed Thomas Edison Electric service expert on November 23, 2026.
Where this job was
Bensalem, Pennsylvania, in Bucks. Electrical service in Bensalem
Related
- More panel upgrade case studies
- Panel Replacement: how we do this job
- More jobs from the Bensalem office
- Electrical service in Bensalem
- Failed Breaker and Storm Damage at Service in Honey Brook, PA: 100 Amp Panel Replacement
- Scorched Panel Connections and Carbon Buildup in Morrisville, PA: 100 Amp Panel Replacement
- More jobs by Hector M.
- Our electrical services
- Contact Thomas Edison Electric