By Eli I., Service expert Lebanon office
Job at a glance
- Location
- Red Lion, PA
- Service
- Panel Replacement
- When
- October 2026
- Service expert
- Eli I.
- Called about
- a problem with the electrical panel
- Service size
- 200 amp
- Panel brand
- Square D
- Visits
- 2
- Options offered
- 2
- Inspection
- Passed
What this type of job typically costs
$7,425 to $11,875
Panel replacement, everything on the job
From 856 jobs we completed in the last 18 months.
The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.
Range updated November 10, 2026.
About this service →A Red Lion client contacted Thomas Edison Electric about a problem with their electrical panel. The home needed both panel work and a way to connect a portable generator.
The client's problem
The client was experiencing issues with their electrical panel and wanted to address the situation while also adding the ability to power their home with a portable generator during outages.
What our service expert found
The service expert evaluated the existing setup and found that the home had two separate panels that could be consolidated into a single, more efficient unit. Combining the panels would simplify the electrical system and create space for adding generator connection capability.
Options we presented
The service expert presented options including a 200 amp main breaker panel replacement and a 30 amp twist lock receptacle for generator connection.
200 amp main breaker panel replacement (the client chose this one)
30 amp twist lock receptacle (the client chose this one)
The solution
The client chose both options to address their panel needs and add generator capability. Over two visits, the team installed a new 42 space 200 amp main breaker panel with a 225 amp bus, consolidating the original two panels into one streamlined unit. They added whole house surge protection to safeguard the home's electronics and appliances. The team also installed a 30 amp circuit with a weatherproof outdoor twist lock receptacle, allowing the client to safely connect their portable generator. The completed work passed electrical inspection.
Work performed
Installed 42 space 200 amp main breaker panel with 225 amp bus
Consolidated two existing panels into one unit
Added whole house surge protector
Ran new 30 amp circuit for generator connection
Installed weatherproof outdoor box with twist lock receptacle
Completed electrical inspection
What we installed
- QO115 Square D QO Breaker Single Pole 15 Amp× 5
- QO120 Square D QO Breaker Single Pole 20 Amp× 3
- QO220 Square D QO Breaker Two Pole 20 Amp
- QO230 Square D QO Breaker Two Pole 30 Amp
- QO250 Square D QO Breaker Two Pole 50 Amp
- Square D UF Cover 42 Space
- QOM2200MM Square D MainBreaker 200 Amp
- QO 42 Space 200 Amp Main Breaker Panel 225 Amp Bus
- Square D Homeline HOM2175SB Surge Protector
- Mulberry 76791, 1G Single Receptacle Maxi Semi Gloss White Metal Plate
- Pass & Seymour L1520-R - Turnlok Single Receptacle 4W 20A 3P 250V
- Romex Wire 10 and 3 NM Price Per Foot× 25
Why pricing varies
No two homes are wired the same. On this job, the price came down to:
- Service size and whether the main breaker rating changes
- Condition of the existing enclosure, bus bars and breakers
- Grounding and bonding that must be brought up to current code at the same time
- Service entrance conductors and the meter can, when they are part of the scope
- Utility coordination and permit requirements in the jurisdiction
- Surge, AFCI and GFCI protection added during the changeout
- Panel brand and breaker selection
- Accessibility of the panel location and any drywall or masonry work around it
- Code corrections found once the deadfront is off
A service expert prices your job after seeing it, and you approve the price before any work starts.
Why it matters in Red Lion
Consolidating multiple panels into a single modern unit reduces complexity and makes future electrical work easier for homeowners. In York County, where storms can cause extended power outages, having a dedicated generator inlet allows safe and convenient backup power without running extension cords through windows or doors. Whole house surge protection helps shield sensitive electronics from voltage spikes common during power restoration.
Common questions
Why would I consolidate two electrical panels into one?
Combining panels simplifies your electrical system and makes it easier to manage circuits in one location. It also frees up space and can make future electrical additions more straightforward.
What is a twist lock receptacle for a generator?
A twist lock receptacle is a special outlet that securely connects your portable generator to your home's electrical system. The locking mechanism prevents accidental disconnection during use.
Why do I need whole house surge protection with a new panel?
Surge protection guards your appliances and electronics from voltage spikes that can occur during storms or when power is restored after an outage. Installing it at the panel protects your entire home rather than just individual outlets.
Does panel replacement work require an electrical inspection?
Yes, panel replacements typically require a permit and inspection to verify the work meets current electrical codes. The inspection confirms the installation is safe and properly completed.
Project photos
The service expert on this job
Eli I.
Service expert
More about Eli →Reviewed by a licensed Thomas Edison Electric service expert on November 9, 2026.
Where this job was
Red Lion, Pennsylvania, in York. Electrical service in Red Lion
Related
- More panel upgrade case studies
- Panel Replacement: how we do this job
- More jobs from the Lebanon office
- Electrical service in Red Lion
- Main Breaker Failed and the Power Went Out in Springfield, PA: 200 Amp Panel and Service Upgrade
- 200 Amp Panel and Service Upgrade in Allentown, PA
- More jobs by Eli I.
- Our electrical services