Bath Fan Call Uncovers a Water Damaged Service in Scranton, PA: 200 Amp Panel and Service Upgrade

Scranton, PA Job done October 2026 Panel Replacement

A bath fan problem in Scranton revealed water damage and corrosion in the electrical service. The team replaced the panel and completed the fan installation.

Electrical panel interior showing corroded wire connections and damaged insulation requiring repair or replacement in Scranton, PA
Cameron J.

By Cameron J., Service expert Allentown office

Job at a glance

Location
Scranton, PA
Service
Panel Replacement
When
October 2026
Service expert
Cameron J.
Called about
a bathroom exhaust fan
Service size
200 amp
Panel brand
Siemens
Visits
2
Options offered
5
Inspection
Passed

What this type of job typically costs

$7,425 to $11,875

Panel replacement, everything on the job

From 856 jobs we completed in the last 18 months.

The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.

Range updated November 10, 2026.

About this service →

A Scranton, Pennsylvania homeowner contacted Thomas Edison Electric about a bathroom exhaust fan that was causing electrical problems. What began as a fan installation issue led to the discovery of a much larger concern with the home's electrical service.

The client's problem

The client explained that another electrician had attempted to install a new bath fan but left the job incomplete, with the old fan removed and an open hole in the ceiling. After that work, the bathroom switch began turning off power in the kitchen and tripping the breaker.

What our service expert found

The service expert performed troubleshooting and identified that improper wiring connections from the previous work were causing the breaker to trip whenever the bathroom switch was engaged. During this investigation, the expert also discovered serious problems with the home's 200 amp electrical service. The outdoor riser wire had become severely sun-dried, a condition where exposure to the elements causes wire insulation to crack and break open. This damage had allowed water to enter the meter pan and main panel box, resulting in rust and corrosion inside the electrical equipment. The riser wire was running through the porch roof without proper PVC protection, and the compromised insulation was affecting the integrity of the neutral wire.

Electrical panel interior showing corroded wire connections and damaged insulation requiring repair or replacement in Scranton, PA
Finding 1
Electrical panel with main breaker, circuit breakers, and wiring during installation or service work in Scranton, PA
Finding 2
HVAC ductwork installation through ceiling with wrapped insulation and electrical wiring visible in attic space in Scranton, PA
Finding 3
Digital utility meter installed on exterior brick wall with protective enclosure and conduit wiring in Scranton, PA
Finding 4

Options we presented

The service expert laid out the work in levels, from finishing the bath fan to replacing the whole electrical service.

  • Finish the bath fan installation and correct the wiring

  • The bath fan plus a full 200 amp service replacement and a whole home surge protector (the client chose this one)

  • All of that plus a whole home safety inspection

  • Venting the bath fan to the outside

The solution

The client chose to address both the immediate bath fan issue and the underlying electrical service problems. The team first disconnected the improper wiring connections that were causing the breaker to trip. They then installed the client-provided bath fan, mounting it to the drop ceiling using ceiling brackets and a support stud running wall to wall, with the existing bathroom stack switch reconnected correctly to operate the fan and light separately. For the service replacement, the team installed a new 200 amp meter base with an outdoor disconnect, replaced the deteriorated riser with a protected PVC service mast and new weatherhead, and installed a new Siemens 40 space 200 amp main breaker panel. A complete grounding system was installed including ground rods and a water bond. A whole home surge protector was added to protect the electrical system. The work required a utility coordination and an underwriter inspection.

Work performed

  • Troubleshot and corrected improper wiring connections from previous work

  • Installed client-provided bathroom exhaust fan with ceiling brackets and wall-to-wall support stud

  • Reconnected bathroom stack switch to properly control fan and light separately

  • Replaced 200 amp service mast with PVC protection, new meter base, and outdoor disconnect

  • Installed Siemens 40 space 200 amp main breaker panel on pressure treated plywood

  • Installed complete grounding system with ground rods, ground bridge, and water bond

  • Added whole home surge protection device

What we installed

  • PVC 2" Conduit SCH 40× 20
  • PVC 2" TA
  • Porcelain Cat Eye, Topaz 1003
  • XHHW - 4 and 0 Black Stranded AL Aluminum× 90
  • Milbank Square Hub Bolt On 2" 4 Bolts 200 Amp
  • Conduit Mast and Service Entrance Head 2" PVC
  • Siemens BR 15 Amp Single Pole Breaker× 12
  • Siemens BR Q120 20 Amp Single Pole Breaker× 12
  • Siemens BR 20 Amp 2 Pole Breaker
  • Siemens BR 30 Amp 2 Pole Breaker
  • Siemens BR 50 Amp 6 AWG 2 Pole Breaker
  • Siemens ec3gb212 21-Position Ground Bar Kit

Why pricing varies

No two homes are wired the same. On this job, the price came down to:

  • Service size and whether the main breaker rating changes
  • Condition of the existing enclosure, bus bars and breakers
  • Grounding and bonding that must be brought up to current code at the same time
  • Service entrance conductors and the meter can, when they are part of the scope
  • Utility coordination and permit requirements in the jurisdiction
  • Surge, AFCI and GFCI protection added during the changeout
  • Panel brand and breaker selection
  • Accessibility of the panel location and any drywall or masonry work around it
  • Code corrections found once the deadfront is off

A service expert prices your job after seeing it, and you approve the price before any work starts.

Why it matters in Scranton

Older homes in Scranton and throughout Lackawanna County often have electrical services that have been exposed to decades of harsh northeastern Pennsylvania weather. Sun-dried wiring and water intrusion into electrical equipment create serious safety hazards that can go unnoticed until a seemingly unrelated problem brings an electrician to the home. Addressing these issues proactively helps protect both the home and its occupants.

Common questions

What does it mean when wire becomes sun-dried?

Sun-dried wire has been damaged by prolonged exposure to sunlight and weather, causing the protective insulation to crack, become brittle, and break open. This exposes the wire to moisture and compromises its ability to safely carry electricity.

Why would water in an electrical panel cause rust and corrosion?

When water enters electrical equipment through damaged wire insulation or gaps in the enclosure, it reacts with metal components over time. This corrosion weakens connections, can cause arcing, and degrades the overall safety and reliability of the electrical system.

Why is PVC protection important for service entrance wiring?

PVC conduit shields the service entrance wires from direct exposure to sunlight, rain, and temperature extremes. Without this protection, wire insulation deteriorates much faster, leading to the kind of damage that allows water intrusion into electrical equipment.

Why would a bathroom switch trip a breaker in another room?

The two are usually on the same circuit or share a neutral. A miswired switch or fan connection can create a short or tie two circuits together, so flipping the switch trips the breaker and takes other rooms with it. The wiring has to be traced and corrected, not just reset.

Project photos

Open electrical service panel mounted on brick wall showing main disconnect, breakers, and conduit connections with proper wire routing in Scranton, PA
Main electrical panel with circuit breakers installed and wired, showing organized cable routing and connections in Scranton, PA
Main electrical panel with 200A Siemens breaker, service entrance wiring with red, black, and green conductors installed in conduit in Scranton, PA
Electrical service panel mounted on brick wall with main breaker, disconnect switches, and conduit installed in Scranton, PA
Cameron J.

The service expert on this job

Cameron J.

Service expert

More about Cameron →

Reviewed by a licensed Thomas Edison Electric service expert on November 16, 2026.

Where this job was

Scranton, Pennsylvania, in Lackawanna. Electrical service in Scranton

Related

Need the same kind of help at home?

Book online or call us 24/7. A service expert will look at your system and walk you through your options.

The Thomas Edison Electric office team and electricians together

Careers at Thomas Edison Electric

Here We Grow Again...

Like what you see? We are always looking for great new team members.

See Our Openings