Open Now

Main Breaker Failed and the Power Went Out in Springfield, PA: 200 Amp Panel and Service Upgrade

Springfield, PA Job done August 2026 Panel Replacement

Water intrusion had corroded this Springfield home's electrical equipment. The team installed a new 200 amp panel, service mast, grounding system, and surge protection.

Main electrical panel with circuit breakers installed and labeled, mounted on exterior wall with outlet box visible in Springfield, PA
Mike V.

By Mike V., Service expert Drexel Hill office

Job at a glance

Location
Springfield, PA
Service
Panel Replacement
When
August 2026
Service expert
Mike V.
Called about
a problem with the electrical panel
Service size
200 amp
Panel brand
Siemens
Visits
2
Options offered
3
Inspection
Passed

What this type of job typically costs

$7,425 to $11,875

Panel replacement, everything on the job

From 856 jobs we completed in the last 18 months.

The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.

Range updated November 10, 2026.

About this service →
Before
Main electrical panel with circuit breakers and wiring during installation or service work in Springfield, PA
After
Main electrical panel with circuit breakers installed and labeled, mounted on exterior wall with outlet box visible in Springfield, PA

A Springfield, Pennsylvania client called about a problem with their electrical panel after experiencing a sudden loss of power throughout the home. The issue had started that day, and the client requested emergency service to diagnose and resolve the failure.

The client's problem

The client noticed that power was entering the home but dying immediately, with the main breaker in the electrical panel appearing to have failed. They had attempted some basic troubleshooting and were concerned about the safety of the situation.

What our service expert found

The service expert found that the service cable weatherhead was defective, allowing water to enter the meter enclosure over time. This water intrusion had caused significant rust and corrosion inside the electrical equipment, and the main breaker had failed as a result. The meter enclosure itself was over 50 years old. The grounding system was outdated with no ground rods present, which did not meet current code requirements. The home also had no surge protection installed, leaving appliances and electronics vulnerable to power surges.

Options we presented

The service expert presented three options to replace the failed equipment and bring the service up to current safety standards.

  • 100 amp, 30 space Siemens panel and meter with surge protection

  • 200 amp, 40 space Siemens panel and meter with new service cable, whole house surge protection and a grounding system

  • 200 amp, 40 space Siemens panel and meter with a PVC mast, a main breaker disconnect, whole house surge protection and a grounding system (the client chose this one)

The solution

The client chose the comprehensive upgrade featuring a 40 space 200 amp Siemens panel with a new meter base, PVC mast with main breaker disconnect, whole house surge protection, and a full grounding system. The team replaced the defective weatherhead and meter enclosure with a new 200 amp overhead service mast using PVC pipe. They installed a new Siemens 40 space 200 amp main breaker panel and ran new SER cable to connect the components. A main breaker disconnect was added at the exterior for enhanced safety. The crew installed a complete grounding system with ground rods to meet current code. They added an Eaton whole house surge protective device at the service entrance and installed a new GFCI receptacle as part of the work. Power was restored the following afternoon after the utility company connected the new service.

Work performed

  • Replaced defective meter enclosure and weatherhead with new 200 amp PVC service mast

  • Installed Siemens 40 space 200 amp main breaker panel

  • Ran new 200 amp SER cable to connect service equipment

  • Added outdoor main breaker disconnect for safety

  • Installed complete grounding system with ground rods

  • Added whole house surge protective device at service entrance

  • Installed GFCI receptacle

What we installed

  • Siemens Type PN 40 Space 200 Amp Main Breaker Panel
  • Siemens BR 15 Amp Single Pole Breaker× 12
  • Siemens BR Q120 20 Amp Single Pole Breaker× 12
  • Siemens BR 20 Amp 2 Pole Breaker
  • Siemens BR 30 Amp 2 Pole Breaker
  • Siemens BR 50 Amp 6 AWG 2 Pole Breaker
  • Mulberry 76401, 1G Decora Semi Gloss White Metal Plate
  • Pass & Seymour 1597-TRW 15A 125V Self-Test GFCI Tamper-Resistant, White Outlet
  • Siemens ec3gb212 21-Position Ground Bar Kit
  • Eaton ECCVH200R 200 Amp Breaker Enclosure
  • PVC 2" Conduit SCH 40× 20
  • PVC 2" TA

Why pricing varies

No two homes are wired the same. On this job, the price came down to:

  • Service size and whether the main breaker rating changes
  • Condition of the existing enclosure, bus bars and breakers
  • Grounding and bonding that must be brought up to current code at the same time
  • Service entrance conductors and the meter can, when they are part of the scope
  • Utility coordination and permit requirements in the jurisdiction
  • Surge, AFCI and GFCI protection added during the changeout
  • Panel brand and breaker selection
  • Accessibility of the panel location and any drywall or masonry work around it
  • Code corrections found once the deadfront is off

A service expert prices your job after seeing it, and you approve the price before any work starts.

Why it matters in Springfield

Homes in Delaware County with older electrical equipment are particularly susceptible to water intrusion and corrosion, especially when original weatherheads and meter enclosures have been in service for decades. Upgrading to a modern panel with proper grounding and surge protection helps protect the home from electrical fires and shields sensitive electronics from damaging power surges. A main breaker disconnect at the exterior also provides firefighters and utility workers with a safe way to cut power in an emergency.

Common questions

How does water get into electrical panels and meter enclosures?

Water typically enters through deteriorated weatherheads, cracked conduit, or worn seals around the meter base. Over time, this moisture causes rust and corrosion on internal components, which can lead to equipment failure and safety hazards.

Why do I need a main breaker disconnect on the outside of my home?

An exterior main breaker disconnect allows firefighters and utility workers to quickly shut off power to your home in an emergency without needing to enter the building. It also provides a convenient way to de-energize the system for maintenance or repairs.

What should I do if my main breaker will not stay on?

Do not keep forcing it. A main breaker that trips at once or will not reset usually points to a failed breaker, water or corrosion in the equipment, or a fault on the service. Leave it off and call a licensed electrician. If you see smoke or smell burning, call 911 and your utility.

Why would my grounding system need to be updated?

Electrical codes have evolved over the years to improve safety, and older homes often have grounding systems that no longer meet current standards. Proper grounding with ground rods helps direct fault currents safely into the earth, reducing the risk of electrical shock and fire.

Project photos

Installed electrical service panel with disconnect switch and breaker on exterior wall in Springfield, PA
Ceiling opening with tangled electrical wiring, outlet box, and junction box during rough-in installation in Springfield, PA
Exterior electrical service installation with conduit and cable management on residential home exterior wall in Springfield, PA
Siemens electrical panel interior showing main breaker, bus bars, and service conductors during installation or service work in Springfield, PA
Siemens electrical panel with main breaker, bus bars, and service entrance wiring installed on exterior wall in Springfield, PA

Filmed on the job

Watch the walkthrough

Mike V. filmed this on the job in Springfield, so you can see what we found and what the work involved.

Mike V.

The service expert on this job

Mike V.

Service expert

More about Mike →

Reviewed by a licensed Thomas Edison Electric service expert on November 9, 2026.

Where this job was

Springfield, Pennsylvania, in Delaware. Electrical service in Springfield

Related

Need the same kind of help at home?

Book online or call us 24/7. A service expert will look at your system and walk you through your options.

The Thomas Edison Electric office team and electricians together

Careers at Thomas Edison Electric

Here We Grow Again...

Like what you see? We are always looking for great new team members.

See Our Openings