By Jason Z., Service expert Lebanon office
Job at a glance
- Location
- Lancaster, PA
- Service
- Power Restored After an Outage
- When
- July 2026
- Service expert
- Jason Z.
- Called about
- losing power to all or part of the home
- Visits
- 2
- Options offered
- 2
What this type of job typically costs
$575 to $1,400
Power restored (no power or partial power)
From 142 jobs we completed in the last 18 months.
The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.
Range updated November 10, 2026.
About this service →A Lancaster, Pennsylvania homeowner contacted Thomas Edison Electric after waking up to find the living room and internet without power. The breaker had tripped and would not stay in place, and the client mentioned this circuit had tripped before when multiple devices were running.
The client's problem
The client noticed that the living room had lost all power, including the internet. When they tried to reset the breaker, it would not snap back into position. They also recalled that this same breaker had tripped in the past when the television, internet, and lights were on while running the vacuum.
What our service expert found
The service expert performed a thorough troubleshooting evaluation and opened all receptacles and switches in the affected area. The inspection revealed that all devices throughout the living room were backstabbed, an older wiring method where wires are pushed into the back of outlets and switches rather than secured with screws. This connection method loosens over time and creates resistance, which can cause overheating and tripping. The service expert identified a specific switch that, when turned on, would trip the entire circuit. The expert labeled this switch and advised against using it until repairs could be made, then showed the client photos documenting the backstabbed connections and explained the fire hazard they presented.
Options we presented
The service expert presented two options to address the widespread backstabbed wiring throughout the home.
Whole home redevice (replace all 120 volt receptacles and switches in home) (the client chose this one)
40 Space Siemens Panel Replacement, whole home redevice (replace all 120 volt receptacles and switches in home)
The solution
The client chose to proceed with a whole home redevice, replacing all 120-volt receptacles and switches throughout the home. The team returned for a second visit and installed all new outlets and switches in accessible locations, eliminating the backstabbed connections that had been causing the circuit to trip and creating a fire risk.
Work performed
Performed troubleshooting evaluation of affected living room circuit
Opened and inspected all receptacles and switches in the living room
Identified and labeled the switch causing the circuit to trip
Documented backstabbed wiring connections with photos
Replaced all 120-volt receptacles throughout the home
Replaced all 120-volt switches throughout the home
Secured all new devices with proper screw terminal connections
Why pricing varies
No two homes are wired the same. On this job, the price came down to:
- Where the fault is: a breaker, a connection, the panel or the service
- How many circuits are affected
- Whether the utility has to disconnect and reconnect
- Parts replaced to fix the cause
A service expert prices your job after seeing it, and you approve the price before any work starts.
Why it matters in Lancaster
Homes built in the early 1990s and before often have backstabbed wiring connections that deteriorate over time. In Lancaster and throughout Lancaster County, many homes of this era share similar electrical characteristics. Replacing aging outlets and switches with properly secured connections reduces the risk of electrical fires and prevents nuisance breaker trips.
Common questions
What does it mean when a breaker trips and will not reset?
When a breaker trips and refuses to stay in the on position, it typically indicates a fault on the circuit that the breaker is protecting against. This could be caused by a short circuit, a ground fault, or an overloaded circuit with damaged wiring. A service expert should evaluate the circuit before attempting to use it again.
What is backstabbed wiring and why is it a problem?
Backstabbed wiring refers to a connection method where wires are pushed into holes in the back of outlets and switches rather than being secured with screws. Over time, these connections loosen and create resistance, which generates heat and can lead to arcing, tripped breakers, or electrical fires.
How do I know if my home has backstabbed outlets?
Backstabbed outlets were commonly installed in homes from the 1970s through the 1990s because they were faster to install. Signs of failing backstabbed connections include outlets that feel warm, intermittent power loss, or breakers that trip frequently. An electrician can inspect your outlets to determine the connection method used.
Why replace all the outlets and switches instead of just the one causing problems?
When one backstabbed device fails, it indicates that all devices installed the same way are aging similarly and at risk of the same failure. Replacing all outlets and switches at once addresses the root cause throughout the home and prevents future circuit failures or potential fire hazards.
Project photos
The service expert on this job
Jason Z.
Service expert
Jason is a service expert with Thomas Edison Electric. He has completed more than 2,400 jobs for clients in Berks, Dauphin and Lebanon counties. His most common calls are troubleshooting, outlets and switches, panel upgrades and lighting and ceiling fans.
More about Jason →Reviewed by a licensed Thomas Edison Electric service expert on November 9, 2026.
Where this job was
Lancaster, Pennsylvania, in Lancaster. Electrical service in Lancaster
Related
- More electrical repair case studies
- Power Restored After an Outage: how we do this job
- More jobs from the Lebanon office
- Electrical service in Lancaster
- Outlets Stopped Working in Kingston, PA: Failed Outdoor GFCI Outlets Replaced
- Main Breaker Failed and the Power Went Out in Springfield, PA: 200 Amp Panel and Service Upgrade
- More jobs by Jason Z.
- Our electrical services