By Jason Z., Service expert Reading office
Job at a glance
- Location
- Pottsville, PA
- Service
- Panel Replacement
- When
- August 2026
- Service expert
- Jason Z.
- Called about
- knob and tube wiring in the home
- Service size
- 200 amp
- Panel brand
- Siemens
- Visits
- 4
- Options offered
- 2
- Inspection
- Passed
What this type of job typically costs
$7,425 to $11,875
Panel replacement, everything on the job
From 856 jobs we completed in the last 18 months.
The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.
Range updated November 10, 2026.
About this service →A client in Pottsville, Pennsylvania contacted Thomas Edison Electric after recently purchasing an older home with concerns about the existing electrical system. The property, a large historic residence, had knob and tube wiring and multiple areas where power had stopped working.
The client's problem
The client noticed that electricity had gone out in several parts of the home over time, with lights and outlets no longer functioning in various rooms. They were also aware the house had outdated wiring, including ungrounded two prong outlets throughout the property.
What our service expert found
The service expert discovered that the main electrical panel was not receiving a full phase of power, which traced back to a failing utility line from the pole to the house. The existing main panel and two sub panels were outdated, with improper wiring feeding the sub panels. The home also had ungrounded two prong outlets, which pose a safety risk for modern electronics and appliances. The service expert explained that while a full rewire was not immediately necessary, upgrading the panels and adding surge protection would help protect the older wiring still in the walls.
Options we presented
The service expert presented two options for bringing the electrical system up to current standards. Both included a new main panel, meter, grounding system, surge protection, and two sub panels, but one option also addressed the ungrounded outlets throughout the home.
40-Space 200-Amp Siemens Panel with Meter, SEU, Whole House Surge Protection and Grounding System outdoor disconnect, 2 100 amp sub panels, 200ft SER cable for sub panels, two 100 amp breakers for subpanels, replace all ungrounded receptacles with GFCI (the client chose this one)
40-Space 200-Amp Siemens Panel with Meter, SEU, Whole House Surge Protection and Grounding System outdoor disconnect, 2 100 amp sub panels, 200ft SER cable for sub panels, two 100 amp breakers for subpanels
The solution
The client chose the comprehensive option that included replacing all ungrounded receptacles with GFCI outlets. The team installed a new 40 space 200 amp Siemens main panel with a new meter base, service entrance cable, and outdoor disconnect. They added a full grounding system and whole house surge protection at the main panel. Two 100 amp sub panels were installed with new feeder cables, and during the project, a third sub panel was added to properly serve additional circuits. The team replaced ungrounded two prong outlets with GFCI receptacles throughout the home. On a follow up visit, the crew resolved a lighting circuit issue by reconnecting a missing neutral, restoring function to ceiling and exterior lights. The work required four visits and passed electrical inspection.
Work performed
Installed 40 space 200 amp Siemens main breaker panel with new meter base and outdoor disconnect
Replaced service entrance cable and mast
Installed full grounding system
Added whole house surge protection at main panel
Installed two 100 amp sub panels with feeder cables
Installed third sub panel with surge protection and new feeder
Replaced ungrounded two prong outlets with GFCI receptacles
Repaired lighting circuit by reconnecting neutral
What we installed
- Mulberry 76401, 1G Decora Semi Gloss White Metal Plate× 21
- Pass & Seymour 1597-TRW 15A 125V Self-Test GFCI Tamper-Resistant, White Outlet× 21
- Siemens BR 15 Amp Single Pole Breaker× 48
- Siemens BR Q120 20 Amp Single Pole Breaker× 48
- Siemens BR 20 Amp 2 Pole Breaker× 4
- Siemens BR 30 Amp 2 Pole Breaker× 4
- Siemens BR 50 Amp 6 AWG 2 Pole Breaker× 4
- Siemens ec3gb212 21-Position Ground Bar Kit× 4
- Eaton CHSPT2ULTRA Type 1 Surge Protective Device× 4
- Acorn Clamp 5 and 8 Acorn Direct Burial Bronze Ground Rod Clamp× 2
- Ground Clamp Aluminum 1 and 2 to 1"
- Intersystem Bonding Grounding Bridge - ARLGB5
Why pricing varies
No two homes are wired the same. On this job, the price came down to:
- Service size and whether the main breaker rating changes
- Condition of the existing enclosure, bus bars and breakers
- Grounding and bonding that must be brought up to current code at the same time
- Service entrance conductors and the meter can, when they are part of the scope
- Utility coordination and permit requirements in the jurisdiction
- Surge, AFCI and GFCI protection added during the changeout
- Panel brand and breaker selection
- Accessibility of the panel location and any drywall or masonry work around it
- Code corrections found once the deadfront is off
A service expert prices your job after seeing it, and you approve the price before any work starts.
Why it matters in Pottsville
Many older homes in Pottsville and throughout Schuylkill County were built with wiring methods that are no longer considered safe by modern standards. Upgrading the electrical panels and adding GFCI protection allows homeowners to use the home safely without immediately tearing into walls for a full rewire. Proper grounding and surge protection are especially important in areas with aging infrastructure, where power fluctuations can damage sensitive electronics.
Common questions
Can I keep my old wiring if I upgrade the electrical panel?
In many cases, yes. Upgrading the panel, adding proper grounding, and installing surge protection can make older wiring safer to use. However, a qualified electrician should evaluate the condition of the existing wiring to determine if it can remain in service.
What is the purpose of GFCI outlets in a home with ungrounded wiring?
GFCI outlets provide shock protection even when a grounding wire is not present. They detect imbalances in electrical current and shut off power quickly, making them an accepted solution for replacing ungrounded two prong outlets.
Why would a home need multiple sub panels?
Large homes or homes with additions often need sub panels to distribute power efficiently to different areas. Sub panels reduce the length of wire runs and make it easier to manage circuits in various parts of the house.
What does whole house surge protection do?
Whole house surge protection is installed at the electrical panel and helps absorb voltage spikes before they reach your appliances and electronics. This is especially useful in older homes where wiring may be more vulnerable to damage from power surges.
Project photos
The service expert on this job
Jason Z.
Service expert
Jason is a service expert with Thomas Edison Electric. He has completed more than 2,400 jobs for clients in Berks, Dauphin and Lebanon counties. His most common calls are troubleshooting, outlets and switches, panel upgrades and lighting and ceiling fans.
More about Jason →Reviewed by a licensed Thomas Edison Electric service expert on November 9, 2026.
Where this job was
Pottsville, Pennsylvania, in Schuylkill. Electrical service in Pottsville
Related
- More panel upgrade case studies
- Panel Replacement: how we do this job
- More jobs from the Reading office
- Electrical service in Pottsville
- Main Breaker Failed and the Power Went Out in Springfield, PA: 200 Amp Panel and Service Upgrade
- 200 Amp Panel and Service Upgrade in Allentown, PA
- More jobs by Jason Z.
- Our electrical services
- Contact Thomas Edison Electric