By Jason Z., Service expert Lebanon office
Job at a glance
- Location
- Shippensburg, PA
- Service
- Panel Replacement
- When
- November 2026
- Service expert
- Jason Z.
- Called about
- a circuit that had stopped working
- Service size
- 200 amp
- Panel brand
- Siemens
- Visits
- 2
- Options offered
- 4
- Inspection
- Passed
What this type of job typically costs
$7,425 to $11,875
Panel replacement, everything on the job
From 856 jobs we completed in the last 18 months.
The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.
Range updated November 10, 2026.
About this service →A Shippensburg, Pennsylvania homeowner contacted Thomas Edison Electric about a circuit that had stopped working. The client also needed a dedicated line for a dehumidifier and sump pump they were having installed.
The client's problem
The client noticed that a circuit in their home had stopped working. They also had six two prong receptacles upstairs that needed updating and wanted a dedicated line installed for new basement equipment.
What our service expert found
When the service expert removed the panel cover, they discovered rust and corrosion damage inside the electrical equipment. Water had been getting into the electrical system through the outdoor service entrance, creating a safety hazard. The service expert showed the client both the interior panel damage and the exterior entry point where moisture was infiltrating the system.
Options we presented
The service expert presented four options, from the outlet and circuit work alone to a full 200 amp service upgrade.
Six GFCI receptacles and a dedicated 20 amp line for the dehumidifier
The same, plus whole home surge protection and updated grounding
200 amp, 40 space Siemens panel and meter with whole house surge protection, a grounding system and an outdoor disconnect, plus the receptacles and the dedicated line
That 200 amp package with the service cable riser in PVC conduit (the client chose this one)
The solution
The client chose the most comprehensive protection package. The team returned to install a new 40 space 200 amp Siemens panel with a new meter base, an SEU riser protected by PVC conduit, an outdoor disconnect, whole house surge protection, and a complete grounding system. They also installed six GFCI receptacles to replace the outdated two prong outlets and ran a dedicated 20 amp circuit for the dehumidifier and sump pump. After restoring power, the team verified that all components functioned properly.
Work performed
Installed 40 space 200 amp Siemens main breaker panel
Replaced 200 amp service mast with new meter base and outdoor disconnect
Installed SEU riser in PVC conduit for weather protection
Added whole house surge protective device
Installed full grounding system
Replaced six outlets with GFCI receptacles
Ran dedicated 20 amp circuit for dehumidifier and sump pump
What we installed
- Mulberry 76401, 1G Decora Semi Gloss White Metal Plate× 8
- Pass & Seymour 1597-TRW 15A 125V Self-Test GFCI Tamper-Resistant, White Outlet× 8
- Siemens BR 15 Amp Single Pole Breaker× 12
- Siemens BR Q120 20 Amp Single Pole Breaker× 12
- Siemens BR 20 Amp 2 Pole Breaker
- Siemens BR 30 Amp 2 Pole Breaker
- Siemens BR 50 Amp 6 AWG 2 Pole Breaker
- Siemens ec3gb212 21-Position Ground Bar Kit
- Eaton CHSPT2ULTRA Type 1 Surge Protective Device
- Acorn Clamp 5 and 8 Acorn Direct Burial Bronze Ground Rod Clamp× 2
- Ground Clamp Aluminum 1 and 2 to 1"
- Intersystem Bonding Grounding Bridge - ARLGB5
Why pricing varies
No two homes are wired the same. On this job, the price came down to:
- Service size and whether the main breaker rating changes
- Condition of the existing enclosure, bus bars and breakers
- Grounding and bonding that must be brought up to current code at the same time
- Service entrance conductors and the meter can, when they are part of the scope
- Utility coordination and permit requirements in the jurisdiction
- Surge, AFCI and GFCI protection added during the changeout
- Panel brand and breaker selection
- Accessibility of the panel location and any drywall or masonry work around it
- Code corrections found once the deadfront is off
A service expert prices your job after seeing it, and you approve the price before any work starts.
Why it matters in Shippensburg
Older homes in Cumberland County often have service equipment exposed to the elements, and moisture intrusion can cause corrosion that compromises electrical safety over time. Replacing damaged equipment before it fails completely prevents potential fire hazards and ensures reliable power for essential systems like sump pumps. A properly grounded and surge protected electrical system also safeguards appliances and electronics from voltage irregularities common in rural and suburban areas.
Common questions
How does water get inside an electrical panel?
Water typically enters through the service entrance where cables connect to the meter and panel. Aging weatherheads, deteriorated seals, or improperly installed conduit can allow rain and moisture to travel down the wiring and into the equipment.
Why is corrosion inside a panel dangerous?
Corrosion can weaken electrical connections, causing circuits to fail or create hot spots that increase fire risk. Rust on breakers and bus bars can also prevent them from tripping properly during an overload or short circuit.
What is the benefit of PVC conduit on the service entrance?
PVC conduit provides a waterproof barrier around the service entrance cables, preventing moisture from reaching the panel. It is also resistant to rust and corrosion, making it a durable long term solution for protecting outdoor electrical components.
Why do I need a dedicated circuit for a dehumidifier or sump pump?
These appliances draw significant power, especially when starting up, and sharing a circuit with other devices can cause tripped breakers or voltage drops. A dedicated circuit ensures reliable operation and prevents interference with other outlets in your home.
Project photos
The service expert on this job
Jason Z.
Service expert
Jason is a service expert with Thomas Edison Electric. He has completed more than 2,400 jobs for clients in Berks, Dauphin and Lebanon counties. His most common calls are troubleshooting, outlets and switches, panel upgrades and lighting and ceiling fans.
More about Jason →Reviewed by a licensed Thomas Edison Electric service expert on November 16, 2026.
Where this job was
Shippensburg, Pennsylvania, in Cumberland. Electrical service in Shippensburg
Related
- More panel upgrade case studies
- Panel Replacement: how we do this job
- More jobs from the Lebanon office
- Electrical service in Shippensburg
- Main Breaker Would Not Reset in Shippensburg, PA: 200 Amp Panel and Service Upgrade
- Rust and Corrosion Inside the Panel in Harrisburg, PA: 200 Amp Panel and Service Upgrade
- More jobs by Jason Z.
- Our electrical services
- Contact Thomas Edison Electric