By Mike V., Service expert North Wales office
Job at a glance
- Location
- Lansdale, PA
- Service
- Panel Replacement
- When
- August 2026
- Service expert
- Mike V.
- Called about
- a problem with the electrical panel
- Service size
- 100 amp
- Panel brand
- Siemens
- Visits
- 3
- Options offered
- 3
- Inspection
- Passed
What this type of job typically costs
$7,425 to $11,875
Panel replacement, everything on the job
From 856 jobs we completed in the last 18 months.
The middle half of what our clients paid for this work alone across Pennsylvania and New Jersey, before discounts, refreshed every month. A licensed service expert sees your home and gives a written price before any work starts.
Range updated November 10, 2026.
About this service →A Lansdale client contacted Thomas Edison Electric after power went out in their living room and lights along the circuit began flickering. The home was undergoing renovations, and the client was unable to reset a tripped breaker in their older electrical panel.
The client's problem
The client noticed that a breaker would not reset, leaving part of the home without power. Lights on the affected circuit were flickering, and the client suspected the panel needed replacement since it had not been updated since the house was built in 1969.
What our service expert found
The service expert found rust and corrosion inside the meter enclosure, a failed breaker that could not be reset, and an overloaded circuit. The panel was over fifty years old with outdated grounding and backstab receptacles throughout the home. The main service jumper cable was too short and lacked a proper connector, and the underground meter enclosure showed significant deterioration. These conditions posed safety concerns and prevented reliable power distribution to the home.
Options we presented
The service expert presented panel replacement options to address the aging equipment and safety issues.
Underground meter enclosure
20-Space 40-Circuit Siemens Panel with Surge Protection (the client chose this one)
30-Space Siemens Panel with Surge Protection
The solution
The client chose a 20-space 40-circuit Siemens panel with surge protection along with a new underground meter enclosure. Over three visits, the team replaced the deteriorated meter base, installed the new main breaker panel, ran new service entrance cable, added ground rods and bridged them to the existing grounding system, installed a whole-house surge protective device, replaced a GFCI outlet as part of the panel work, and replaced a standard receptacle. The work passed municipal inspection.
Work performed
Replaced 100-amp underground meter enclosure on existing riser
Installed Siemens 20-space 100-amp main breaker panel
Ran new service entrance cable up to 10 feet
Added ground rods and bridged to existing grounding system
Installed whole-house surge protective device at service entrance
Replaced GFCI outlet and standard duplex receptacle
Coordinated municipal inspection
What we installed
- Siemens Type PN 20 Space 100 Amp Main Breaker Panel
- Nipple 1 and 2" Rigid Conduit Offset
- RACO 192, 1900 Box 1-1 and 2D - 1 and 2-3 and 4KO Raised Grnd
- RACO 808C, 1900 GFCI Cover
- Eaton TRGF15W 15 Amp 125 VAC GFCI Tamper-Resistant White Outlet
- Siemens ec3gb212 21-Position Ground Bar Kit
- Eaton CHSPT2ULTRA Type 1 Surge Protective Device
- Acorn Clamp 5 and 8 Acorn Direct Burial Bronze Ground Rod Clamp× 2
- Intersystem Bonding Grounding Bridge - ARLGB5
- Ground Rod 5 and 8" Copper
- CU Bare #6 Solid Price Per Foot× 25
- AL SEU 1 and 0-1 and 0-1 and 0 Price Per Foot× 12
Why pricing varies
No two homes are wired the same. On this job, the price came down to:
- Service size and whether the main breaker rating changes
- Condition of the existing enclosure, bus bars and breakers
- Grounding and bonding that must be brought up to current code at the same time
- Service entrance conductors and the meter can, when they are part of the scope
- Utility coordination and permit requirements in the jurisdiction
- Surge, AFCI and GFCI protection added during the changeout
- Panel brand and breaker selection
- Accessibility of the panel location and any drywall or masonry work around it
- Code corrections found once the deadfront is off
A service expert prices your job after seeing it, and you approve the price before any work starts.
Why it matters in Lansdale
Many homes in Lansdale and throughout Montgomery County were built in the 1960s and still have their original electrical panels. Aging panels with corroded components and outdated grounding can lead to failed breakers, unreliable power, and increased fire risk. Replacing this equipment brings the electrical system up to current safety standards and supports the demands of modern appliances and home renovations.
Common questions
Why would a breaker fail to reset?
A breaker that will not reset is often damaged internally or has reached the end of its lifespan. In older panels, breakers can wear out after decades of use, and attempting to force a reset can be dangerous if the breaker or panel has underlying problems.
How does rust in a meter enclosure affect my electrical system?
Rust and corrosion inside a meter enclosure can compromise the integrity of electrical connections and allow moisture to reach critical components. Over time, this deterioration can lead to unreliable power delivery and potential safety hazards.
What is the benefit of whole-house surge protection?
A whole-house surge protective device installed at the main panel helps shield your electrical system and connected appliances from voltage spikes caused by lightning or utility fluctuations. It provides a first line of defense before surges can reach sensitive electronics inside the home.
Why would ground rods need to be added during a panel replacement?
Older homes often have grounding systems that do not meet current standards. Adding ground rods and properly bonding them to the electrical system improves safety by providing a reliable path for fault currents to dissipate into the earth.
Project photos
The service expert on this job
Mike V.
Service expert
More about Mike →Reviewed by a licensed Thomas Edison Electric service expert on November 9, 2026.
Where this job was
Lansdale, Pennsylvania, in Montgomery. Electrical service in Lansdale
Related
- More panel upgrade case studies
- Panel Replacement: how we do this job
- More jobs from the North Wales office
- Electrical service in Lansdale
- Main Breaker Failed and the Power Went Out in Springfield, PA: 200 Amp Panel and Service Upgrade
- 200 Amp Panel and Service Upgrade in Allentown, PA
- More jobs by Mike V.
- Our electrical services
- Contact Thomas Edison Electric